Vent gas odor during light-oil transfer
Challenge: A client transferring 320 m³ of oil containing 1,200 ppm H2S from storage tanks to a liquid hauler had insufficient odor control from its activated charcoal and iron oxide installations.
Solution: A patented Gas Taxi scrubber (160 cfm). GT-615 and 32% MEA triazine were each run to a 4 ppm outlet breakthrough.
Result: The client achieved a 30-day runtime with GT-615, compared with 13 days for its 300 lb charcoal drum. It also saved on disposal and handling, and operators reported that the sulfur odors during fluid transfer were gone.
Continuous injection in a hydrocarbon line
GT-615 was injected into 150 m of 8-inch line feeding a stock tank, against inlet H2S of 4,200-6,000 ppm. In Guard's trial, GT-615 reached outlet levels of 2.5-25 ppm. 38% MEA triazine produced 48-500 ppm at comparable injection rates. Adding a static mixer is recommended to reduce chemical consumption.
Gas sweetening by injection
At 0.485 mmscf/day and 540 ppm H2S, GT-615 reduced daily chemical consumption by 7% and annual operating costs by 22% compared with 38% triazine.
From our capabilities overview
- WWTP odor: scavenger misting achieved an 80% odor reduction at a wastewater treatment plant.
- Condensate: a 60% scavenger blend produced sweeter condensate with lower chemical use than MEA triazine.
- Gas Taxi: media lasted more than twice as long as conventional media.
All results are Guard Products' own field results. Results depend on site conditions.